Part Number Hot Search : 
PD50N CPC1001N SY100 SM160 S10A40PT 70HFR10 1001S BZT52C
Product Description
Full Text Search
 

To Download 1991738 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
PM5313
SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER
REVISION B DEVICE ERRATA
ISSUE 4: JUNE 2001 PRODUCTION
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
REVISION HISTORY
Issue No. 4 3 2 1 Issue Date June 2001 September 2000 May 2000 January 2000 Details of Change Rev B errata updated to include known errors in issue 6 datasheet Rev B errata updated to reflect production release errata Rev A errata edited to reflect Rev B errata Document created.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
CONTENTS 1 ISSUE 4 ERRATA ..................................................................................2 1.1 2 3 DEVICE IDENTIFICATION ..........................................................2
FUNCTIONAL DEFICIENCIES OVERVIEW ..........................................3 SPECTRA-622 REVISION B FUNCTIONAL DEFICIENCY DETAILS ................................................................................................4 3.1 RX ALARMS ................................................................................4 3.1.1 INVALID PRDI CODE INSERTION...................................4 3.1.2 RECEIVE ALARM CONSEQUENTIAL ACTIONS CLEARING ......................................................5
4
SPECTRA-622 ISSUE 6 DATASHEET ERRATA ...................................6 4.1 4.2 4.3 4.4 4.5 TIU2PERDI BIT NOT DEFINED ..................................................6 DOOL (DATA OUT OF LOCK) DECLARATION - PAGE 111 ....................................................................................6 SLLBEN BIT DESCRIPTION CORRECTION - PAGE 145, PAGE 431............................................................................7 TFPI PIN DESCRIPTION - PAGE 28 ..........................................7 TRANSMIT TRANSPORT OVERHEAD INPUT TIMING - PAGE 604 ...................................................................8
5
CONTACTING PMC-SIERRA, INC. .....................................................10
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
i
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
1
ISSUE 4 ERRATA This document is the errata notice for Revision B, production release of the SPECTRA-622 (PM5313-BI) and issue 6 SPECTRA-622 datasheet. The issue 6 SPECTRA-622 datasheet (PMC-1981162) and issue 4 errata supersede all prior editions and versions of the datasheet.
1.1
Device Identification The information in this document applies to the PM5313 SPECTRA-622 revision B device only. The device revision code is marked at the end of the Wafer Batch Code on the face of the device (as shown in Figure 1). PM5313 SPECTRA-622 Revision B is packaged in a 520 pin Super BGA package.
Figure 1: PM5313 SPECTRA-622 Branding Format
Pin A1 Index Mark PMC Logo
SPECTRA Logo
SPECTRA-622
PM5313-BI C B Myyww
TOP VIEW SCALE : 2:1 (APPROX.)
TM
Part Number Wafer Batch Code Assembly Date Code
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
2
FUNCTIONAL DEFICIENCIES OVERVIEW This section outlines the known functional discrepancies between the PM5313 SPECTRA-622 revision B production release device and the Issue 6 SPECTRA622 datasheet. The errata are explained in more detail in sections 3 of this document. Please note that the errata contained in this document are preliminary. Table 1 FUNCTIONAL DEFICIENCIES SUMMARY LIST
# Discrepancy Workaround? Modes Affected 3.1 Rx Alarms 3.1.1 3.1.2 Invalid PRDI code insertion Rx alarms consequential action clearing Yes Yes Rx PRDI codes STS-12c mode, STS-3c mode
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
3 3.1
SPECTRA-622 REVISION B FUNCTIONAL DEFICIENCY DETAILS Rx Alarms
3.1.1 Invalid PRDI code insertion Description For concatenated applications, PRDI & Enhanced PRDI codes for LOPCON and PAISCON are not reported correctly (for local reporting and RAD). Workarounds Correct RDI/ERDI events can be forced * In software, by polling the LOPCON and PAISCON alarm indications in registers of slave slices, then forcing Path RDI/ERDI in the transmit stream by setting PERDIEN, PERDISRC (register 1n50h) PFDI, PERDI6, and PERDI7 (register 1n59h) according to the application requirements and Table 13 in the description of register 1n59h. In hardware, by monitoring the RDI/ERDI indications in the slave timeslots of the RAD port, and using external hardware (FPGA/CPLD) to set the RDI/ERDI bit times in the master timeslot of the TAD port.
*
Performance without workaround * RDI and ERDI are not automatically asserted in the transmit stream of SPECTRA 622 when the receive path is in LOPCON or PAISCON alarm. * On RAD port, correct PRDI values are observed on slave time slots but not on the master timeslot.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
4
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
3.1.2 Receive Alarm Consequential Actions Clearing Description On the Drop bus, PAIS consequential action takes 10 frames to clear when exiting any received path error condition in STS-12c (STM-4-4c) mode, and 3 frames to clear when exiting loss of pointer (LOP) condition in STS-3c (STM1/AU4) mode. Workaround Path BIP errors (B3) and H1, H2 values should be monitored on the Drop bus to ensure that the PAIS alarm condition has cleared, and that the Drop bus is again carrying valid payload and pointer. Performance without Workaround SPECTRA-622 will output an enabled NDF and a valid pointer value on the Drop bus when the path error condition has been cleared. However, the all-ones alarm indication is not cleared in all the path-processing slices until 10 frames after the enabled NDF appears. Therefore, the payload and concatenation indicators will be temporarily corrupted. After 10 frames, a valid pointer (with no enabled NDF), payload, and concatenation indicators are output on the Drop bus. The transition from PAIS to valid data cannot be easily detected without monitoring overhead.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
5
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
4
SPECTRA-622 ISSUE 6 DATASHEET ERRATA This section contains errata in the issue 6 SPECTRA-622 datasheet. 1. unaltered text is unchanged to add context to changes 2. new material is bold and italicized 3. deleted material is bold and italicized with strikethrough 4. comments specific to this document are in italics
4.1
TIU2PERDI Bit not defined All references to TIU2PERDI bit should be ignored. The TIU2PERDI bit is not defined in the SPECTRA-622 device. Path enhanced RDI assertion due to path trace identifier (mode 1) unstable (TIU) events is enabled via the TIUPERDI bit only (register 0119H). The description of the TIUPERDI bit has not changed, and reads: TIUPERDI: When set high, the TIUPERDI bit enables path enhanced RDI assertion when path trace identifier (mode 1) unstable (TIU) events are detected in the receive stream. If enabled, when the event occurs, bit 6 of the G1 byte (or the RAD output PRDI6 bit position) is set high while bit 7 of the G1 byte (or the RAD output PRDI7 bit position) is set low. When TIUPERDI is set low, trace identifier (mode 1) unstable events have no effect on path RDI. In addition, this bit has no effect when PERDI_EN is set low.
4.2
DOOL (data out of lock) declaration - page 111 Section 11.1.1 Clock Recovery Unit , should state that the PLL will revert to the reference clock if there are no data transitions after 96 bit periods. The clock recovery unit recovers the clock from the incoming bit serial data stream. The clock recovery unit is fully compliant with SONET/SDH jitter tolerance requirements. The clock recovery unit utilizes a low frequency reference clock to train and monitor its clock recovery PLL. Under loss of signal conditions, the clock recovery unit will continue to output a line rate clock that is locked to this reference for keep alive purposes. The clock recovery unit utilizes a
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE 6
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
77.76 MHz reference clock. The clock recovery unit provides status bits that indicates whether it is locked to data or the reference and also supports diagnostic loopback and a loss of signal input that squelches normal input data. Initially, the PLL locks to the reference clock, REFCLK+/-. When the frequency of the recovered clock is within 488 ppm of the reference clock, the PLL attempts to lock to the data. Once in data lock, the PLL reverts to the reference clock if no data transitions occur in 80 96 bit periods or if the recovered clock drifts beyond 488 ppm of the reference clock.
4.3
SLLBEN bit description correction - page 145, page 431 The following highlighted text should be removed from section 11.8.3 Transmit Pointer Interpreter Processor (TPIP): The TPIP is held in reset in DS3 mode, DS3ADDSEL = `1' and when SLLBEN = '0' (reg 1n00). When held in reset, TPIP registers cannot be accessed. In addition, the following highlighted sentence should be removed from the description of the SLLBEN bit in register 1n00H: SLLBEN: When set high, the system side line loopback enable bit (SLLBEN) activates line loopback of the receive STS-1 (STM-0/AU3) or equivalent stream processed by the corresponding RPPS. The receive stream replaces the transmit STS-1 (STM0/AU3) or equivalent stream from the ADD bus. When SLLBEN is set low, system side line loopback of the corresponding receive stream is disabled, the data stream from the ADD bus is processed normally. The system side line loopback can only be enabled when the DS3 ADD Bus stream is disabled via the DS3ADDSEL register bit in the SPECTRA-622 TPPS Path and DS3 configuration register. SLLBEN has not effect when DS3ADDSEL is set high. When SLLBEN is low, TPIP is held in reset - TPIP registers cannot be accessed.
4.4
TFPI Pin description - page 28 The TFPI pin description should be modified to include timing specifications in parallel mode:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
7
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
In serial mode, TFPI is sampled on the rising edge of TCLK. In parallel mode, TFPI is sampled on the rising edge of TDCK
4.5
Transmit Transport Overhead Input Timing - page 604 The following highlighted changes should be made to Table 49: Transmit Transport Overhead Input Timing to correctly indicate hold time requirements for the TSOW, TSUC, and TLOW signals. Table 2 - Transmit Transport Overhead Input Timing
Symbol tSTLD tHTLD tSTSLD tHTSLD tSTOW tHTOW tHTOW tSTOH tHTOH tSTTOH tHTTOH Description TLD Set-up Time to TLDCLK TLD Hold Time to TLDCLK TSLD Set-up Time to TSLDCLK TSLD Hold Time to TSLDCLK TSOW, TLOW, TSUC Set-up Time to TOWCLK TSOW, TLOW, TSUC Hold Time to TOWCLK (non-gapped mode) TSOW, TLOW, TSUC Hold Time to TOWCLK (gapped mode) TOH Set-up Time to TOHCLK TOH Hold Time to TOHCLK TTOH, TTOHEN Set-up Time to TTOHCLK TTOH, TTOHEN Hold Time to TTOHCLK Min 250 0 250 0 250 0 250 250 0 17 0 Max Units ns ns ns ns ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
8
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
9
PRODUCTION ERRATA PMC-1991738 ISSUE 4
PM5313 SPECTRA-622
SONET/SDH PAYLOAD EXTRACTOR/ALIGNER ERRATA
5
CONTACTING PMC-SIERRA, INC. PMC-Sierra, Inc. 8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: +1 (604) 415-6000 Apps Support: +1 (604) 415-4533 Fax: +1 (604) 415-6200 Document Information:document@pmc-sierra.com Corporate Information: info@pmc-sierra.com Application Information: apps@pmc-sierra.com Web Site: http://www.pmc-sierra.com
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 2001 PMC-Sierra, Inc. PMC-1991738 (P4) Issue date: June 2001
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS' INTERNAL USE
10


▲Up To Search▲   

 
Price & Availability of 1991738

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X